Burlington Field Maintenance Shop

Project

Burlington Field Maintenance Shop

Mixed Use

Burlington, KY | 2024

  • 25K GSF
  • 1 Company

About

"Faced with an outdated and undersized leased building for their field maintenance operations in Burlington, KY, the Kentucky National Guard, Department of Military Affairs, and Commonwealth of Kentucky (DECA) sought to replace their aging facility. The 25,000 SF facility features a 4-bay maintenance work area with adjacent rooms for supplies, tools, POL storage, batteries, janitorial needs, and laundry. Additionally, the southern end of the building houses administrative offices, a telecom/server room, classrooms, and a physical fitness room."

Project Owner

Kentucky National Guard & Commonwealth of Kentucky (DECA)

Is the project Net Zero Energy or Net Zero Energy Ready?

Net Zero (Achieving)

Project Size in GSF

25K

Category of height

Low-Rise

How is the building all-electric for heating?

Ground-source Heat Pump

Is the service hot water all-electric?

Yes

What is the primary system type for domestic hot water?

Ground-source heat pump

On-site renewable energy

0%

Is the owner purchasing off-site renewable energy to offset all electricity consumption?

No

Site EUI Energy Use Intensity is the amount of energy a project uses per square foot over the course of a year. Site EUI = Annual Energy Use (kBtus) / Building(s) Area (ft²) / One Year (yr)

35.0 kBtu/sf/year

The EUI is

Modeled

What is the climate zone for this project?

4A Mixed Humid

Websites for more information

Project Team

MEP/FP Engineering
  • CMTA

    In Business Since 1968

    3.3M GSF

    23 Projects

    3 Professionals

Energy Engineering
  • CMTA

    In Business Since 1968

    3.3M GSF

    23 Projects

    3 Professionals