About
6 Elkins Street will be an approximately 97,000 gross square foot research laboratory development, including office, laboratory, research and development uses, along with approximately 4,400 square feet of publicly accessible retail/restaurant space and approximately 8,250 square feet of incubator lab space. The proposal also includes approximately 48 parking spaces in a one-level below grade garage.
Is the project Net Zero Energy or Net Zero Energy Ready?
Net Zero Ready
Project Size in GSF
97K
Category of height
Low-Rise
How is the building all-electric for heating?
Air-source Heat Pump
Is the service hot water all-electric?
No
What is the primary system type for domestic hot water?
Heat recovery heat pump
What other systems are used for hot water?
Fossil-fuel fired
On-site renewable energy
0%
Is the owner purchasing off-site renewable energy to offset all electricity consumption?
No
The construction cost difference from "conventional" to being net zero "ready" (including incentives) for this building is
We didn't calculate the cost premium
Site EUI Energy Use Intensity is the amount of energy a project uses per square foot over the course of a year. Site EUI = Annual Energy Use (kBtus) / Building(s) Area (ft²) / One Year (yr)
111.0 kBtu/sf/year
The EUI is
Modeled
Carbon Emissions Intensity (CEI)
5.70kg/CO2e/sf
What is the climate zone for this project?
5A Cool Humid